Brand Name : P+F

Model Number : RD0-FB-Ex4

Certification : CE

Place of Origin : SINGAPORE

MOQ : 1pc

Price : negotiable

Payment Terms : T/T

Supply Ability : 100pcs per month

Delivery Time : on request

Packaging Details : standard carton packing

Design / Mounting : Cabinet installation

Installation in hazardous area : Zone 1 / Div. 2

Rated voltage : 32 ... 16 V DC

Connection type : screw terminal

Mounting : DIN rail mounting

Mass : 1050 g

Contact Now

P+F Fieldbus Barrier RD0-FB-Ex4

The FieldBarrier, a device coupler for DIN rail mounting, connects 4 instruments with intrinsic safety (Ex ia/Ex ib) and short circuit current limitation

at each output. This ensures proper operation of the segment during faults or hot work at the spur.
High power on the trunk enables maximum cable lengths and device count in any hazardous area. The integrated fieldbus terminator features
high-availability design and is selectable.
Output terminals with a choice of fixed or plug-in screw terminals connect 1 device each. LEDs simplify troubleshooting and help decrease repair
time. Any grounding and shielding concept is possible based on FieldConnex® enclosure solutions.

General specifications

Design / Mounting

Cabinet installation

Installation in hazardous area

Zone 1 / Div. 2

Fieldbus connection

Main cable (Trunk)

Connection

input (Trunk IN): terminals 3+, 4-, 5s
output (Trunk OUT): terminals 7-, 8+, 6s

Rated voltage

32 ... 16 V DC

Rated current

31 mA ... 26 mA (without load)
77 mA ... 115 mA (at 20 mA load per input)
120 mA ... 209 mA (at 40 mA load per input)
135 mA ... 241 mA (short-circuit on all outputs)

Voltage drop

trunk IN to trunk OUT 100 mV max.

Number of couplers

max. 4 per segment

Outputs

Number of devices per output

1

Connection

output 1: terminals 10+, 11-, 12S shield;
output 2: terminals 13+, 14-, 15S shield;
output 3: terminals 16+, 17-, 18S shield;
output 4: terminals 19+, 20-, 21S shield

Rated voltage

10 ... 13 V

Rated current

max. 43 mA

Short-circuit current

50 mA

Indicators/operating means

LED voltage Fieldbus

green: on, bus voltage existent

LED status output

red flashing: short-circuit

Galvanic isolation

Main wire/outputs

isolation is not affected by interference according to EN 50020, voltage peak value 375 V

Directive conformity

Electromagnetic compatibility

Directive 2014/30/EU

EN 61326-1:2013

Standard conformity

Electromagnetic compatibility

NE 21:2006

Degree of protection

IEC/EN 60529

Fieldbus standard

IEC 61158-2

Climatic conditions

DIN IEC 721

Corrosion resistance

acc. to ISA-S71.04-1985, severity level G3

Ambient conditions

Ambient temperature

-50 ... 70 °C (-58 ... 158 °F)

Storage temperature

-40 ... 85 °C (-40 ... 185 °F)

Mechanical specifications

Connection type

screw terminal

Core cross section

up to 2.5 mm2

Housing

see figure 1

Housing material

Polycarbonate

R... DIN rail housing

PA 6.6

Degree of protection

IP20

Mass

1050 g

Mounting

DIN rail mounting

P+F Fieldbus Barrier RD0-FB-Ex4 Cabinet Installation Design with 32 ... 16 V DC Rated Voltage

P+F Fieldbus Barrier RD0-FB-Ex4 Cabinet Installation Design with 32 ... 16 V DC Rated Voltage


Product Tags:

P+F Fieldbus Barrier

      

RD0-FB-Ex4 Fieldbus Barrier

      

Cabinet Installation Fieldbus Barrier

      
Quality P+F Fieldbus Barrier RD0-FB-Ex4 Cabinet Installation Design with 32 ... 16 V DC Rated Voltage for sale

P+F Fieldbus Barrier RD0-FB-Ex4 Cabinet Installation Design with 32 ... 16 V DC Rated Voltage Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: SC Automation Limited
*Subject:
*Message:
Characters Remaining: (0/3000)